We use cookies to enhance the usability of our website. If you continue, we'll assume that you are happy to receive all cookies. More information. Don't show this again.
Antibody staining overlaps with antibody HPA019665. Antibody staining overlaps with antibody HPA001427.
Validated
Antibody staining overlaps with antibody HPA019665. Antibody staining overlaps with antibody HPA000880.
Validated
Antibody staining overlaps with antibody HPA001427. Antibody staining overlaps with antibody HPA000880.
Standard validation
Approved
Approved
Approved
Figure description
Immunofluorescent staining of human cell line A-431 shows localization to nucleoplasm.
Immunofluorescent staining of human cell line U-251 MG shows localization to nucleoplasm.
Immunofluorescent staining of human cell line A-431 shows localization to nucleoplasm.
Antibody dilution
1:5
1:80
1:25
Literature conformity
The subcellular location is partly supported by literature or no literature is available.
The subcellular location is partly supported by literature or no literature is available.
The subcellular location is partly supported by literature or no literature is available.
IMMUNOHISTOCHEMISTRY
Antibody HPA000880
Antibody HPA001427
Antibody HPA019665
Standard validation
Approved
Approved
Figure description
Immunohistochemical staining of human cerebellum shows strong cytoplasmic positivity in Purkinje cells.
Immunohistochemical staining of human cerebellum shows strong cytoplasmic positivity in Purkinje cells.
Expression
RNA: detected in 37 tissues Protein: detected in 63 cell types
RNA: detected in 37 tissues Protein: detected in 34 cell types
Retrieval
HIER pH6
HIER pH6
Antibody dilution
1:35
1:15
Literature conformity
No avaliable gene/protein characterization data.
No avaliable gene/protein characterization data.
RNA consistency
Mainly consistent with RNA expression data.
Mainly consistent with RNA expression data.
WESTERN BLOT
Antibody HPA000880
Antibody HPA001427
Antibody HPA019665
Standard validation
Uncertain
Analysis performed using a standard panel of samples. Only bands not corresponding to the predicted size.
Uncertain
Analysis performed using a standard panel of samples. Single band differing more than +/-20% from predicted size in kDa and not supported by experimental and/or bioinformatic data.
Uncertain
Analysis performed using a standard panel of samples. No bands detected.
Figure description
Lane 1: Marker [kDa] 219, 112, 85, 49, 32, 25, 17.5 Lane 2: RT4 Lane 3: U-251 MG Lane 4: A-431 Lane 5: Liver Lane 6: Tonsil
Lane 1: Marker [kDa] 230, 130, 95, 72, 56, 36, 28, 17, 11 Lane 2: RT4 Lane 3: U-251 MG Lane 4: Human Plasma Lane 5: Liver Lane 6: Tonsil
Target mass (kDa)
232.8
232.8
232.8
Antibody dilution
1:500
1:500
1:250
PROTEIN ARRAY
Antibody HPA000880
Antibody HPA001427
Antibody HPA019665
Standard validation
Supported
Pass with single peak corresponding to interaction only with its own antigen.
Supported
Pass with single peak corresponding to interaction only with its own antigen.
Supported
Pass with single peak corresponding to interaction only with its own antigen.
Figure description
Antibody specificity analysis with protein arrays. Predicted and matching interactions are shown in green.
Antibody specificity analysis with protein arrays. Predicted and matching interactions are shown in green.
Antibody specificity analysis with protein arrays. Predicted and matching interactions are shown in green.